Products

Elisa Coagulation Analyser - ARX 3 in 1


The ARX 3 in 1 is a biochemistry ELISA coagulation analyser combined in one system that features 35 direct test keys for test selection and user-friendly software. It offers air purge between samples to avoid carry over and utility mode for self-diagnosis checking.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOSTAT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Biochemistry Analyser - ARX 199 / ARX 199i


The ARX-199 biochemistry analyzer comes with user-friendly software and allows for editing of patient ID and name (12 characters), along with providing the print out of the laboratory name and doctor's name. Other features include onboard memory for storage of 2,000 test results with patient ID, lamp saver mode and optional PS2 keyboard connection.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor print out of laboratory name & Doctor's name

•  For Kinetic test : On line Graph & OD. Graph editing facility. Estimation of result

•  Universal input voltage 90 to 265 V/50 - 60 Hz

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Methods of Assay

•  ABS

•  EP with Factor

•  KIN

•  Fixed time

•  Differential

•  Multipoint up to 10 standards

Technical Specifications

•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From -0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 505, 546, 578, 630 and 670nm. 1 extra position
Bandwidth — 10 nm (± 2nm)
Reading error — ±2% at 2.5 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOSTAT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive, 57 mm wide


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  ASPIRATION SYSTEM
Continuous flow system with Bi-directional peristaltic pump


•  INCUBATOR
37°C for 9 Position Test Tubes & 9 Position Cuvettes


•  PROGRAMMING
Table of tests — up to 200
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 128 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 80W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 40 cm x 32 cm X 16


Biochemistry Analyser - RX 50V


The RX-50V semi-automatic biochemistry analyzer offers triplicate calibration mode for EP / KIN / Fix time and triplicate mode of sampling with mean / SD / CV. It offers user-friendly software, 35 direct test keys for test selection and air purge between samples to avoid carry over.

Primary Features

•  User friendly software

•  End point method - Storage of abs of regent blank in memory / 10 graphs for KIN test

•  Triplicate calibration mode for EP / KIN / Fix time

•  Triplicate mode of sampling with mean / SD / CV

•  Print out of laboratory and doctor's name

•  For kinetic test: On line graph and OD, graph editing facility, estimation of result

•  Air purge between samples to avoid carry over / lamp saver mode

•  35 Direct test keys for test selection

•  Utility mode for self diagnosis checking / 16 bit ADC

•  Sample type: serum / plasma / CSF / urine / whole blood / hemolysate

•  Calculator for lipid profile / globulin ratio / S. Iron TIBC / bilirubin

Technical Specifications

•  Absorbance

•  End Point with standard / factor

•  Kinetics

•  Fixed time

•  Differential

•  Coagulation

•  Multipoint upto 10 standards


•  COAGULATION
INR, ISI Value % / Seconds
Auto / Manual start
Parameters — PT, APTT
Filter — 405 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 700nm interference type
Bandwidth — 10 nm (± 2nm)
Light source — Halogen lamp 12V/20W or 6V/10W
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOSTAT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed / RT
Accuracy — ± 0.1°C


•  INTERFACE
RS - 232 For PC Connection
Parallel Port - For 80 Column Dot Matrix Printer


•  DRY BATH INCUBATOR
13 mm Diameter — 15 Positions
10 mm Diameter — 4 Positions
Default Temperature — 37° C + 0.2° C
3 Inbuilt Timers — T1 / T2 / T3
4 Default Time — 3 Min. / 5 Min. / 10 Min. / 15 Min
1 Location Open — Editable up to 99 Hours / 99 Min
Temperature Setting — 25°C to 45°C
LCD — Alpha Numeric 20 x 2 Lines
Keyboard — Soft Tactile Switches


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro Plastic or Glass


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — PS-2 type


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from300 ml to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 128 KB EEPROM (1000 Test Results)


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Biochemistry Analyser - RX 50


The RX-50 semi-automatic biochemistry analyzer offers triplicate calibration mode for EP / KIN / Fix time and triplicate mode of sampling with mean / SD / CV. It offers user-friendly software, 35 direct test keys for test selection and air purge between samples to avoid carry over.

Primary Features

•  User friendly software

•  End Point Method - Storage of Abs of Reagent blank in memory

•  Editing of patient iD, Name (12 characters), Factor Print out of laboratory name & Doctor's name

•  For Kinetic test: On line Graph & OD. Graph editing facility. Estimation of result

•  Battery Back-up for 90 mins - Optional

•  Air purge between samples

•  Coagulation test like PT with parameters ISI value / INR / Ratio, APTT

•  Storage of 1000 test results in the memory with patient ID

•  PS2 Keyboard connection optional, Lamp Saver mode

•  35 Direct Test Keys for Test Selection

•  Utility Mode for Self diagnostics

•  Sample Type : Serum / Plasma / CSF / Urine / Whole Blood / Hemoiysate

Methods of Calculations

•  Absorbance

•  End Point with standard / factor

•  Kinetics

•  Fixed time

•  Differential

•  Coagulation

•  Multipoint upto 10 standards

Technical Specifications

•  METHODS OF ASSAY
ABS/EP with Factor/KIN/Fix Time/Differential/ Multi point of 10 Standards


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From – 0.1 to 3.0A for 340nm, – 0.1 to 3.5A WL range 405 to 670nm
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 67 0nm interference type
Bandwidth — 8 nm (± 2nm)
Reading Error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A Light source — Quartz Halogen lamp 12 V / 20 W, 2000 hours Optional 6V / 10 W
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOSTAT SYSTEM
Peltier regulated 25°, 30° & 37°C, RT programmed
Accuracy — ± 0.1°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Square micro plastic cuvettes & Round test tube diameter 13mm


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive, 57 mm wide


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  ASPIRATION SYSTEM
Continuous flow cell system with peristaltic pump
Sipping Reagent volume programmable from 100µL to 2000µL Air purge volume: programmable from 30µL to 150µL


•  PROGRAMMING
235 Tests, 9 units, Quality control storage of the last 30 results
Memory — 128 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts


•  POWER / DIMENSIONS
Voltage — 110-220 V± 10%
Frequency — 50 - 60 Hz
Maximum power — <80W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 38 cm x 41 cmx 15 cm
Weight — 6 kgs


Ordering Information

•  830-3000
Model RX-50 Biochemistry semi auto analyzer includes specification as per the list, power cord, spare fuse, dust cover, operating manual, thermal printer roll-2 pcs, waste bottle, waste bottle stand.


•  830-3001
Model RX-50 Biochemistry semi auto analyzer includes flow cell 32ul, filters 340, 405, 450, 505, 546, 578, 630 & 670nm, QC: 3 levels,USB keyboard,power adapter ,dust cover, operating manual, thermal printer roll - 2 nos, waste bottle & stand


•  830-3002
Model RX-50 Biochemistry semi auto analyzer includes stepper motor driven peristaltic pump, flow cell 32ul, filters 340, 405, 505, 546, 578,630, & 670nm, +1 extra position. power cord, spare fuse, dust cover, operating manual, thermal printers roll- 2 pcs, waste bottle, waste bottle stand.


•  830-3003
Model RX-50 Biochemistry semi auto analyzer includes filters 340, 405, 505, 546, 578 & 630 nm, Memory 2000 test results. power cord, spare fuse, dust cover, operating manual, thermal printer roll-2 pcs, waste bottle, waste bottle stand.


•  830-3004
Model RX-50 Biochemistry semi auto analyzer includes halogen lamp 6V-10 W, filter 340, 405, 450, 505, 546, 578,630 & 670nm, stepper motor driven peristaltic pump, Memory 2000 test results. power cord, spare fuse, dust cover, operating manual, thermal printer roll - 2 pcs, waste bottle, waste bottle stand.

Clinical Chemistry Analyser - BS 240


BS-240 is a “CUTE”, multi-functional bench top clinical chemistry analyzer with a throughput at 200 T/H. Though with a compact size, it has achieved a host of advanced functions never before found on a like product in the market, making it an optimal chemistry solution for small laboratories and a back-up tool for mid-to-high end laboratories.

Primary Features

•  COMPACT
One of the smallest 200 T/H chemistry analyzers in the market, achieving maximum space saving


•  FLEXIBLE LOADING
Large capacity of 80 reagent positions and 40 sample positions extendable to 80


•  UTILITY
Step-by-step maintenance guide for easy operation; Upgraded auto-washing system ensures low carryover and low water consumption


•  TECHNOLOGY ENHANCED
Smart-sampling technology enables automatic hemolysate preparation for HbA1c test. Pretreatment-free operation guarantees high productivity


•  EFFICIENT
A minimum of 100μl reaction volume for reagent saving


•  WASHING SYSTEM
Upgraded auto-washing system ensures low carryover and low water consumption

Technical Specifications

•  SYSTEM FUNCTION
Automatic, Discrete, Random Access, Bench-top
STAT sample priority
Throughput — Up to 200 tests/hour, up to 400 tests/hour with ISE
Measuring principles —Absorbance photometry, Turbidimetry, Ion Selective Electrode technology
Methodology
End-point, Fixed-time, Kinetic, optional ISE, Single/Dual/ reagent chemistries, monochromatic / bi-chromatic
Original system pack reagent ready to use
Close system and open system is optional


•  REAGENT/SAMPLE HANDLING
Reagent/Sample tray — 80 positions for reagents and 40 positions for samples in 24-hour refrigerated compartment (2~12℃)
Reagent volume — 10~250μl, step by 0.5μl
Sample volume — 2~45μl, step by 0.1μl
Reagent/Sample probe — Liquid level detection, vertical collision protection and inventory checking, reagent pre-warming
Probe cleaning — Automatic washing for interior and exterior Carry over < 0.05%
Automatic sample dilution — Pre-dilution and post-dilution


•  INTERNAL BAR CODE READER (optional)
Used for sample and reagent programming
Be applicable to various bar code systems of Codabar、ITF (Interleaved Two of Five)、code128、code39、UPC/EAN、Code93
Capable to communicate with LIS in bi-directional mode


•  REACTION SYSTEM
Reaction rotor — Rotating tray, containing 40 cuvettes
Cuvette — Reusable, optical length 5mm
Reaction volume — 100~360μl
Operating temperature — 37℃
Temperature fluctuation — ± 0.1℃


•  ISE MODULE (optional)
Measuring K+, Na+, Cl


•  MIXING UNIT
Independent mixing bar
Cuvette Washing — Washing station with pre-warmed detergent and water


•  OPTICAL SYSTEM
Light Source — Halogen-tungsten lamp
Wavelength — 8 wavelengths, 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorption range — 0~4.0 Abs (10mm conversion), resolution 0.0001Abs
Stray Light — 5.6Abs


•  CONTROL & CALIBRATION
Calibration modes — Linear (one point, two points and multi-points), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola
Control Rules — X-R, L-J, Westgard multi-rule, Cumulative sum check, twin plot


•  OPERATION UNIT
Operation system — Windows 8
Interface — RS-232


•  WORKING CONDITIONS
Power Supply — 200~240V, 50/60Hz, ≤1000VA or 100~130V, 60Hz, ≤1000VA
Dimension — 690 mm (length) ×580 mm (depth) ×595 mm (height)
Weight — 79 kg
Paper — Thermosensitive - 57 mm wide, Easy Loading
Water Consumption — ≤ 4 L/H

Clinical Chemistry Analyser - Unicorn 100+


Fully automatic, discrete, random access clinical chemistry analyser with reaction system & laundry mechanism.

Primary Features

•  Fully automatic, discrete, random access clinical chemistry analyser

•  Continuous STAT sampling & open system

•  Compact customise design with 6 - stop on board laundry mechanism

•  Throughput up to 100 photometric test/hour without ISE

•  50 special plastic cuvettes, available optional quartz cuvettes

•  High speed digital transmit with fully sealed matrix spectrophotometer system (FMSS)

•  On board refrigeration of reagents & sample compartment

•  Available - ready to use system packs


Technical Specifications

•  SYSTEM FUNCTION
Category — Random Access fully automatic chemistry analyser
Throughput — 100 tests/hour without ISE
Methodology — End point, Fixed point, Kinetic
Reagent — Open System
Reagent Position — 40
Sample Position — 40
Minimum reaction volume — 160 µL
Carryover — ≤0.005%
Water consumption — 4.5L/hour
Maximum reaction volume — 450 µL
Principle — Colorimeter, Turbidimetric, Absorbance, ISE (optional)
Test Mode — Regular Mode Signle & Double reagent, Fast mode for End point chemistry
Sample Mode — Random Access, STAT sample priority
Programming — Open system user defined chemistry, profile & calculation chemistry


•  SAMPLE REAGENT MIXING PROBE
Sample Volume — 2-50 µL, step by 0.1 µL
Sample Disc — 40 position
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µl to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Electrolyte Analyser - Microlyte


The Microlyte is an electrolyte analyzer that performs analysis in 60 seconds for whole blood and serum, and plasma/CSF sample, and 120 seconds for urine sample. Other features include user-friendly icon-based operation, automatic programmable calibration cycle, liquid stable reagents and maintenance-free electrodes.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Single Channel Coagulometer - ARX CLOT SC


The ARX-CLOT SC is a semi-automatic single channel coagulometer with on-board storage capability of up to 20 assays and all methods that can be created, edited, copied and deleted. The open system with user-friendly software provides automated cuvette detection and calculation of results in seconds, along with a printout of the graph and results.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Four Channel Coagulometer - ARX CLOT


The ARX-CLOT is a semi-automatic four-channel coagulometer with on-board storage capability up to 20 assays and automatically calculates results in seconds. Other features include an open system with user-friendly software, editable calibration/reference curves up to nine measurement points, and automated cuvette detection and calculation.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Elisa Strip Reader


The Microlisa ELISA strip reader uses the cut-off and multi standard method and features user-friendly software. It comes with onboard memory for storage of 1,000 test results with patient ID and cutoff factor & curve, and an LED lamp.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Elisa Plate Reader


The Elisa Plate Reader offers multiple plate formats with 12 / 24 / 48 and 96 well capability to meet a variety of assay needs. Other features include on-board diagnostic testing, storage capacity of 1,000 test results with patient ID, and system test checks of entire optics path with 12 channel optics.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Elisa Plate Washer


User friendly and total programming control microplates washer. Effortless prime, wash, dispense, soak and aspirate, with built in maintenance programs.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Dry bath Incubator


Dry bath incubator has two different blocks for test tubes & Elisa Plate incubation with heat samples in the field and blood samples prior to coagulation testing. It also comes with incubation up to 65 degree for 48 positions of PCR tubes of COVID-19 reagents.

Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Bilirubinometer


Primary Features

•  User friendly software

•  Editing of patient ID, Name (12 characters), Factor

•  Print out of laboratory name & Doctor's name

•  Coagulation test like PT with Magnetic Stirrer

•  Storage of 2000 test results in the memory with patient ID

•  PS2 Keyboard connection optional

•  Lamp Saver mode


Technical Specifications

•  COAGULATION
Mixing by magnetic motor, stirrer INR, ISI Value %, Seconds Auto, Manual start
Parameters — PT, APTT, Fibrinogen
Filter — 405 nm, 630 nm


•  ELISA STRIP READER
Wells — 8 position
Filters — 405 nm, 450 nm, 630 nm
Methods — Cut-off, Multi standard with EP, KIN, Fix Time
O.D. Range — 405 nm, 630 nm


•  OPTICAL SYSTEM
Principle — Absorption spectrometry
Range of measurement — From 0.1 to 3.0A
Nominal spectral range — Automatic via filter wheel
Filters — 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth — 10 nm (± 2nm)
Reading error — ± 5% at 0.10 A, ± 2% at 1.00 A, ± 2% at 2.00 A
Light source — Halogen lamp
Zero — Automatic
Settings — Monochromatic and Bichromatic readings
Detector — Schottkey type Photodiode - Silicon


•  THERMOST AT SYSTEM
Peltier regulated 25°, 30° & 37°C programmed
Accuracy — ± 0.2°C


•  CUVETTES - DUAL MODE
Flow cell of 18 µL
Removable cuvettes — Macro, Semi-micro & Micro


•  PRINTER
Type — Fast Thermal Graphic
Printing speed — 50 mm/sec
Dots per line — 384 dots/line
Paper — Thermosensitive - 57 mm wide, Easy Loading
Programming — On/Off test wise


•  SCREEN AND KEYBOARD
Screen — Graphic LCD 240 x 128 pixels
Back Light — Blue LED Back lit
Keyboard — Tactile Soft - Touch


•  SUCTION SYSTEM
Continuous flow system with peristaltic gear pump
Sipping volume can be programmed from 200µ l to 5.0 ml


•  PROGRAMMING
Table of tests — up to 235
Table of units — up to 9 units
Quality control storage of the last 30 results
Memory — 512 KB EEPROM


•  QUALITY CONTROL
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules


•  POWER / DIMENSIONS
Voltage — 110-220 V
Frequency — 50 - 60 Hz
Maximum power — 110W
Temperature — 10° to 40° C
Maximum relative humidity — 80%
Dimensions — 45 cm x 41 cm X 17
Weight — 8 kgs


Product Description

•  For End Point Method
Storage of ABS for Reagent Blank

•  For Kinetic Test
On Line Graph and OD. Graph Editing
Facility after the test
Estimation of result during test / delta

•  Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph

•  Storage of cut off value
Storage of multi-standard curve
Robotic Friendly design
Self Check & Self Calibration

•  Programmable measurement positions
Fibre Optic Guide reading chamber
Front loading, Self-centering strip carrier

•  Manual / Auto Start
Single Measuring Channel
Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds

•  Integrated Incubation Timer
Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C


Reagents


We supply the needed reagents hospitals, medical & educational labs

SUBSTRATE

•  Glucose

•  Creatinine

•  Urea

•  Uric Acid


LIPIDS

•  Cholesterol

•  HDL Cholesterol

•  LDL Cholesterol

•  Triglycerides


PROTEIN

•  Albumin

•  Bilirubin

•  Total Protein

•  Hemoglobin

•  Micro Protein


ELECTROLYTES

•  Chloride

•  Iron

•  Calcium

•  Phosphorous


ENZYMES

•  Acid Phosphate

•  Alkaline Phosphate

•  ALT/GPT (Gamma GT)

•  Cretine Kinase Lipase (LDH-L)

•  CK-MB

•  Amylase


Quick Order / Enquiry